Allowable Amperage for class 60 ˘J Shipboard Cable Based on ambient temperature 45 ˘J |
|||||||||||||
ˇ@ |
1.5mm2 |
2.5mm2 |
4mm2 |
6mm2 |
10mm2 |
16mm2 |
25mm2 |
35mm2 |
50mm2 |
70mm2 |
95mm2 |
120mm2 |
150mm2 |
Single Core |
12 |
17 |
22 |
29 |
40 |
54 |
71 |
87 |
105 |
135 |
165 |
190 |
220 |
2 Core |
10 |
14 |
19 |
25 |
34 |
46 |
60 |
74 |
89 |
115 |
140 |
162 |
187 |
3 or 4 Core |
8 |
12 |
15 |
20 |
28 |
38 |
50 |
61 |
74 |
95 |
116 |
133 |
154 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Allowable Amperage for class 70 ˘J Shipboard Cable Based on ambient temperature 45 ˘J |
|||||||||||||
ˇ@ |
1.5mm2 |
2.5mm2 |
4mm2 |
6mm2 |
10mm2 |
16mm2 |
25mm2 |
35mm2 |
50mm2 |
70mm2 |
95mm2 |
120mm2 |
150mm2 |
Single Core |
15 |
21 |
29 |
37 |
51 |
68 |
90 |
111 |
138 |
171 |
207 |
239 |
275 |
2 Core |
13 |
18 |
25 |
31 |
43 |
58 |
77 |
94 |
117 |
145 |
176 |
203 |
234 |
3 or 4 Core |
11 |
15 |
20 |
26 |
36 |
48 |
63 |
78 |
97 |
120 |
145 |
167 |
193 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Allowable Amperage for class 85 ˘J Shipboard Cable Based on ambient temperature 45 ˘J |
|||||||||||||
ˇ@ |
1.5mm2 |
2.5mm2 |
4mm2 |
6mm2 |
10mm2 |
16mm2 |
25mm2 |
35mm2 |
50mm2 |
70mm2 |
95mm2 |
120mm2 |
150mm2 |
Single Core |
20 |
28 |
38 |
48 |
67 |
90 |
120 |
145 |
180 |
225 |
275 |
320 |
365 |
2 Core |
17 |
24 |
32 |
41 |
57 |
77 |
102 |
123 |
153 |
191 |
234 |
272 |
310 |
3 or 4 Core |
14 |
20 |
27 |
34 |
47 |
63 |
84 |
102 |
126 |
158 |
193 |
224 |
256 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Allowable Amperage for class 90 ˘J Shipboard Cable Based on ambient temperature 45 ˘J |
|||||||||||||
ˇ@ |
1.5mm2 |
2.5mm2 |
4mm2 |
6mm2 |
10mm2 |
16mm2 |
25mm2 |
35mm2 |
50mm2 |
70mm2 |
95mm2 |
120mm2 |
150mm2 |
Single Core |
21 |
30 |
40 |
51 |
71 |
95 |
125 |
155 |
190 |
240 |
290 |
340 |
385 |
2 Core |
18 |
25 |
34 |
43 |
60 |
81 |
105 |
135 |
165 |
200 |
|
|
ˇ@ |
3 or 4 Core |
15 |
21 |
29 |
36 |
50 |
67 |
89 |
105 |
135 |
170 |
205 |
240 |
270 |